AIRBORNE FREQUENCY CONVERTER

AFC-7000-1-(50, -60 or -400)

AFC-7000-2-(50, -60 or -400)

Behlman's AFC-7000 is a ruggedly built, modified COTS frequency converter designed to convert three-phase aircraft power to regulated single-phase (115 or 230 VAC) 60 Hz ground power.

The AFC-7000 is ruggedly built to support aircraft takeoffs and landings and designed to meet the input power requirements of MIL-STD-704 and RTCA-DO-160.

In the AFC-7000 you'll find the quality features you expect from Behlman. Low output THD, high efficiency, plus excellent line and load regulation.

There's also a unique overload protection system that folds back voltage to maintain rated current without output waveform distortion. Units are supplied with RS-232 remote control and 28 VDC control of Output On/Off. In addition the unit has provisions for slide mounting.

Small size, rugged construction, quiet operation and high efficiency make the AFC-7000 ideal for use on aircraft to convert aircraft power to ground power.


Features

  • Single rack space (6U high)

  • Rugged construction

  • Unique overload protection

  • Microprocessor controller with Vacuum Fluorescent Display

  • RS-232 or 28VDC Output control


Click here for printable Specifications Sheet

Specifications

INPUT

Voltage:

115/200VAC, +/-10%, 3-Ph, WYE, @ 30 Amps/phase max. (power de-rated above 700HZ.

 Multi Pulse Input Transformer for Low Input Current THD

Frequency:

350-800 Hz 

 

OUTPUT

Voltage:

7000-1: 115VAC, single-phase

7000-2: 230VAC, single-phase

Frequency:

50 Hz, 60 Hz or 400 Hz Accuracy: +/- 0.1 Hz

 Power:
6900 VA
 current:

60 Amps @ 115 V

30 Amps @ 230 V

Current Crest Factor:
3:1
Line Regulation:
+/-0.1% for +/-10% Line change
Distortion:
1.5% THD typical, measured at full load, 115 Volts, 60 Hz
Load Regulation:
+/-0.7% No load to full load
Efficiency:
80% typical
Power Factor:
100% of rated output into any power factor load
 

PROTECTIVE CIRCUITS

Input Protection:
Fast-acting main circuit breaker with guard
Thermal Protection:
Internal temperature sensor prevents heat damage
Constant Current Mode:
Overload automatically causes voltage foldback to provide maximum current without distorting output waveform
Short Circuit Protection:
Short circuit overload electronically latches output open to protect load. Power restored by recycling circuit breaker
 

CONTROLS / INDICATORS

Power On/Off
Circuit breaker
Control/Display
Microprocessor controller with 24 characters X 2 lines Vacuum Fluorescent display. Displays Volts, Frequency, current and Current limit. Fault indicator for Over Voltage (OV), Over Current (OI), Over Temperature (OT), Constant Current (CC) and Short Circuit (OL), Watts (W) and Power Factor (PF) Set Current Limit (with RS-232 interface)
Output On/Off ON- with Safety Interlock connector supplied with unit. ON/OFF- with customer supplies 28VDC. ON/OFF- with RS-232 Interface.
Output Indicator: Indicates output relay is energized
Busy Indicator: Indicated a command is being processed by the microprocessor
Reset Switch: Recessed push-button switch to reset controller
Remote Control:
RS-232 to monitor unit, turn output On/Off and set current limit
 

MECHANICAL & ENVIRONMENTAL

Dimensions:
High-strength 19" (48.3 cm) rack mount chassis, 10.5"H X 22"D (26.7 cm X 55.9 cm)
Weight:
128 lbs (58 kgs)
Air intake: Front and Sides
Cooling: Internal fans
Air Exhaust: Rear
Input Connections: J1 - P/N MS3102-24-10P
Output Connections:
J2 - P/N MS3102-32-17S
Control Connections: J3 - P/N D38999-20WB35PN (Supplied with Safety Interlock plug)
Designed to meet the conditions as defined in MIL-STD-810, Method 520.2
Operating Temperature: -4 to 123 F (-20 to 50 C)
Storage Temperature: -4 to 140 F (-20 to 60 C)
Shock: Designed to meet, 18 impacts of 15G's for the duration of 11+/-1 millisecond.
Vibration: Random Vibration Frequency range of 20 to 1000Hz with Power spectrum density of 0.04g/Hz and from 1KHz to 2KHz beginning at 0.04g/Hz and drop at a linear -6db/octave rate.
Humidity: 0-95% RH non-condensing.
Altitude: Designed to operate at altitudes of 10,000 feet. Can be exposed to 40,000 feet in a non-operating state, and operate normally when returned to 10,000 feet or less.
Fungus: Designed not to afford fungus nutrition
Electromagnetic Interference: Designed to meet or exceed MIL-STD-461E requirements, intended for installation on Aircraft. To meet RE102 requirement, shielded cable shall be used for Input and Output Cabling.
 

ELECTRICAL CONNECTIONS:

J1

Power Input Connector, P/N MS3102-24-10

J2

Power Output Connector, P/N MS3102-32-17S

J3

Control Connector, P/N D38999-20WB35PN (Supplied with Safety Interlock plug)

 

OPTIONS

S
Slides
 

MODEL SELECTION

AFC-7000-1-60-S (AFC-7000 with 115VAC, single-phase, 60 Hz output and optional slides )

 

West Coast

2363 Teller Road / Suite 108,
Newbury Park, CA 91320
TEL (800) 456-2006 - (805) 375-7046
FAX (805) 498-2147

Headquarters:

80 Cabot Court.,
Hauppauge, NY 11788
TEL (800) 874-6727 - (631) 435-0410
FAX (631) 951-4341 * E-mail: sales@behlman.com

Easy Payment, We accept:
MasterCard, Visa, Discover,
American Express

About Behlman | Select a Product | Catalog Request | Support | GSA | Sales/Reps | Orbit Int'l | Home
AC Power Supply/Frequency Converter: Switching | Inverters | UPS | Modified Standard Products
COTS: AC-DCDC-DC | Railroad Signal Source | New Products | Application Notes | Wild Frequency Information Center